What is PEB Structure ?



PEB Structure :- Pre Engineering building (PEB) is pre fabricated steel structure and low cast first construction, This technology used for supper structure of building .

Application PEB Structure :-

  •  Wear House 
  • Parking shad 
  • Passenger terminate building
  • Workshop
  • Railway station 
  • Building 
  • shade
Steel column :- Vertical steel start member are called steel column ,generally used for super structure it may be short column and long column ,sub structure  are RCC and joint by Anchor bolt.


Steel beam:- Horizontal steel start member are called steel beam ,steel beam also called rafter, roof sheeting load and praline load come steel beam.

Z praline:- above beam and connect of another beam is called z praline, z praline not required to paint
 
Sag Rod :- 12mm dia bar two end are thread connect to each praline is called sag rod.

Knoop :- Beam and column cantilever section in steel structure are called Knoop 

GP2 Grouting:-Rcc structure and steel structure joint by anchor bolt and 20mm to 50mm gape are filling by grouting and Gp2 grouting ,like fossroc ,pidilite ,etc

Structure steel testing : various location various type of design and various type of steel section , i am testing report submit but this is example 

Results:               

1.       Tensile Strength:

Name of Materials

Brand/ Specification

Yield Strength

(MPa)

Ultimate Tensile Strength

(MPa)

Method of Testing

SHS 91.5X91.5X3.6

JSW

261

455

IS1608

SHS 180X180X5.0

JSW

257

437

CHS 139.5 OD-4.5

JSW

253

415

SHS 132X132X4.8

JSW

264

463

CHS 88.9 OD-3.2

JSW

252

418

CHS 273.0 OD-8.0

JSW

255

421

CHS 165.1 OD-5.4

JSW

258

440

 1.       Bend Test:

Name of Materials

Brand/ Specification

Bend

Remarks

Method of Testing

SHS 91.5X91.5X3.6

JSW

No visible cracks 

Pass

IS 2329

SHS 180X180X5.0

JSW

No visible cracks 

Pass

CHS 139.5 OD-4.5

JSW

No visible cracks 

Pass

SHS 132X132X4.8

JSW

No visible cracks 

Pass

CHS 88.9 OD-3.2

JSW

No visible cracks 

Pass

CHS 273.0 OD-8.0

JSW

No visible cracks 

Pass

CHS 165.1 OD-5.4

JSW

No visible cracks 

Pass

1.       Flattening Test:


Name of Materials

Brand/ Specification

Bend

Remarks

Method of Testing

SHS 91.5X91.5X3.6

JSW

No visible cracks 

Pass

IS 2328

CHS 139.5 OD-4.5

JSW

No visible cracks 

Pass

SHS 132X132X4.8

JSW

No visible cracks 

Pass

CHS 88.9 OD-3.2

JSW

No visible cracks 

Pass

CHS 165.1 OD-5.4

JSW

No visible cracks 

Pass

 

Comments